The MuleHide product line offers a range of commercial roofing solutions, including EPDM, TPO, Mod Bit, and associated adhesives and fasteners. Installation procedures require adherence to specific temperature guidelines to ensure optimal performance and longevity of the roofing system. This article details installation considerations based on available documentation, focusing on temperature requirements for materials and proper application techniques.
Product Overview
MuleHide provides products for various roofing needs, encompassing complete systems and individual components. The product range includes MuleHide SL Base, a self-leveling silicone base coat designed to prepare uneven roofs for a silicone finish. The company also offers EPDM, TPO, and Mod Bit membrane options, alongside fasteners, termination materials, and adhesives. These products are available through ABC Supply locations nationwide, and territory managers are available to assist with job-specific solutions. Pre-packaged submittals containing product data sheets, sample warranties, and customizable cover pages are also available for professional use.
Temperature Requirements for Installation
Maintaining appropriate temperatures is critical during the installation of MuleHide roofing materials. The documentation emphasizes temperature control for both ambient conditions and the materials themselves.
The ambient temperature must be at least 40°F and rising for a consecutive 48-hour period at the time of installation. This ensures proper adhesion and curing of adhesives and sealants. Specific temperature requirements apply to individual components:
- Membranes: Membranes must be maintained between 60°F and 80°F during installation.
- Primers, Adhesives, and Sealants: These materials must be between 60°F and 80°F prior to use.
- Material Storage: Rolls should be stored on end in a warm environment, maintaining a room temperature between 60°F and 80°F until immediately before use.
Materials that fall outside the specified temperature range, or have been removed from warm storage for more than four hours, must be restored to room temperature (60°F to 80°F) before application. Failure to adhere to these temperature guidelines may compromise the integrity of the roofing system.
Cold-Weather Installation Procedures
The provided documentation specifically addresses installation in cold weather. The overarching requirement is the 40°F and rising ambient temperature sustained for 48 hours. Beyond this, maintaining the material temperatures within the 60°F to 80°F range is crucial. This may necessitate temporary heating solutions to ensure proper application.
Rolling Procedures
Proper rolling of the membrane is a critical step in the installation process. The documentation mandates prompt rolling with a minimum 75-pound roller. Failure to adequately roll the membrane can lead to poor adhesion and potential cracking, compromising the roof’s performance.
Product Support and Resources
MuleHide offers support to contractors throughout the roofing process. Territory managers are available to assist in crafting appropriate solutions for specific projects and can conduct on-site assessments before installation begins. The company also provides access to how-to videos and product specifications. MuleHide emphasizes a commitment to providing durable roofing solutions tailored to individual needs.
Fastening and Attachment
The documentation notes the importance of secure fastening and attachment as part of a comprehensive roofing system. While specific fastening methods are not detailed in the provided materials, the emphasis on this aspect suggests its significance in ensuring long-term roof stability.
Conclusion
Successful installation of MuleHide roofing systems relies heavily on adherence to specified temperature guidelines. Maintaining appropriate ambient and material temperatures, coupled with proper rolling procedures, is essential for achieving optimal adhesion, preventing cracking, and ensuring the longevity of the roof. MuleHide provides resources and support to assist contractors in meeting these requirements, including territory managers, product specifications, and how-to videos. The documentation underscores the importance of careful planning and execution to deliver durable and reliable roofing solutions.

