MrSteam AromaSteam System: Installation, Operation, and Safety Guidelines

The MrSteam AromaSteam system is a fragrance metering pump designed for use with residential and day spa steam rooms. Installation requires specific attention to component placement and electrical connections. The system introduces aromatic oils into the steam pipe, enhancing the steam shower experience. This article details installation procedures, operational considerations, and safety precautions based on available documentation.

System Overview and Components

The AromaSteam system integrates with existing MrSteam steam generators to deliver fragrance. Key components include the steam generator, a 90-degree Tee fitting, a check valve, a fragrance metering pump, and associated tubing. The system’s operation centers around a pump that introduces fragrance into the steam line. The AromaSteam pump is factory wired, but the power cord may require replacement by qualified personnel if damaged. The system is designed for use with specific MrSteam fragrances, currently available in five varieties.

Installation Procedures

Installation of the AromaSteam system involves both installer and homeowner sections, with specific steps for each. Installers should first inspect the AromaSteam pump and packaging for shipping damage. The 90-degree Tee fitting, not supplied with the system, should be located within 5-10 feet of the steam generator on the steam supply line.

The suction tube assembly is typically preassembled, but additional tubing can be obtained by contacting MrSteam Technical Service at 1-800-767-8326 or 1-800-727-8326. Priming the pump requires ensuring the MrSteam fragrance container is full and inserting a short piece of soft injector tube onto the injector tip.

Electrical connection of the AromaSteam pump requires disconnecting power to the steam bath generator and removing the top cover. The request cable from the AromaSteam system should be run through a knockout in the side of the generator, utilizing a strain relief bushing or grommet to prevent chafing.

Regarding tubing connections, the suction hose installation steps should be repeated on the pressure side of the pump. This involves unscrewing the suction end nut from the pump head and assembling the tubing connection as shown in a figure referenced in the documentation (figure not provided in source data).

Mounting the Fragrance Caddy

The fragrance caddy can be mounted on a floor using the two holes at the bottom of the caddy. It is essential to test the caddy for secure mounting after installation.

Operational Considerations

The AromaSteam system features an adjustable setting knob to control the amount of aromatic oil delivered. The system is factory set to deliver a suitable amount for a typical-sized steam room. Users are cautioned not to exceed the maximum setting and to contact MrSteam Technical Service before making any adjustments.

Safety Precautions

The documentation emphasizes several critical safety precautions. The AromaSteam system should not be installed outdoors or in locations where water could freeze. It should also be kept away from flammable or corrosive materials and chemicals. A minimum distance of 1.5 feet should be maintained between the AromaSteam system and heat sources, such as the steam generator or heating system. If this distance cannot be maintained, a radiation plate or heat insulation should be installed.

A warning is prominently displayed regarding flammable liquid and vapor, advising against exposure to sparks, electrical outlets, open flames, and hot surfaces. In the event of a fire, water spray should be used for extinction. The fragrance container should be stored in a cool, dry, and well-ventilated place.

Homeowners are instructed to leave the installation, operation, and maintenance manual with the homeowner. The documentation also includes a warning that the installation, operation, and maintenance manual supplied with the product must be used for installation, operation, and maintenance purposes.

Wiring Schematic and Pump Power-Up

The AromaSteam system includes a wiring schematic detailing the electrical connections. The documentation notes that the AromaSteam system is factory wired, but if the power cord is damaged, it must be replaced by the MrSteam service department or similarly qualified personnel.

Powering up the pump requires a specific initial step during installation. The documentation states that this step only needs to be performed during installation, but does not detail the specific procedure.

System Limitations and Warnings

The documentation cautions against installing the AromaSteam system in locations where water could freeze. It also warns against installation near flammable or corrosive materials. The system is designed for use with specific MrSteam fragrances and adjustments to the oil delivery setting should only be made after consulting with MrSteam Technical Service.

Conclusion

The MrSteam AromaSteam system offers a method for introducing fragrance into a steam shower environment. Proper installation, adhering to the provided safety guidelines, and understanding the operational considerations are crucial for optimal performance and user safety. The system requires careful attention to component placement, electrical connections, and adherence to specified distances from heat sources. Users should consult the complete installation, operation, and maintenance manual supplied with the product for detailed instructions and troubleshooting information.

Sources

  1. MrSteam Feel Good AromaSteam Operation and Installation Instructions
  2. MrSteam AromaSteam

Previous post: Mr. Heater Compact Unit Heater Venting and Installation Guidelines

Next Post: MSD 6014 LS Ignition Control: Installation, Configuration, and Updates