The Thetford Sani-Con 600 Series and similar macerator pumps are designed for domestic use to receive and pump away sewage waste and water from various fixtures, including WC pans, showers, vanities, and bidets. These pumps are typically used in enclosed wet-bay applications. Installation requires adherence to specific guidelines to ensure proper function and longevity. This article details installation considerations, connection procedures, and operational parameters based on available documentation.
Product Overview and Applications
The macerator pump is a compact unit intended for domestic sewage waste management. It automatically activates upon flushing a WC or inflow from connected fixtures like vanities. The documentation specifies that the unit is designed to handle waste from a standard P-trap WC pan, as well as showers, vanities, and bidets. The Sani-Con 600 Series is specifically noted as being used in enclosed wet-bay applications. Customer service and technical support are available at 800-543-1219 and 800.444.7210 option 2, respectively.
Installation Requirements
Several key requirements must be met during installation. The macerator pump must be directly coupled to the spigot (outlet) of the WC pan. It is crucial that the pump is located on the same floor level as all incoming fixtures; installation in a pit or in-ground opening is prohibited. All horizontal pipe runs should have a minimum fall of 1:100. If a vertical rise is necessary, it should occur at the beginning of the run. Discharge pipework must be solvent UPVC. When using vertical lifts, only Ø 20MM pressure pipe should be used. All elbows used in the piping should be 2 x 45˚ bends.
Connection Procedures
The documentation details specific procedures for connecting the macerator pump to various fixtures. For connecting the inlet, the connector should be attached to the top entry using a metal hose clip (B). A second hose clip (B) secures the incoming waste pipe. The connector has a small diameter side that faces the pump lid and a larger diameter side that accepts the incoming waste line. Extra sanitary appliances can be connected, with details available in figures 1 and 2 of the referenced documentation. Venting should be consistent with common plumbing practice and Australian Standards AS 3500 10:10 & 6:7:4 where possible.
Pumping Parameters and Dimensions
The performance curve indicates an output of 100-110 liters/min. The maximum vertical pumping height is 5 meters. Horizontal runs must maintain a 1:100 fall. The documentation provides dimensions and overall measurements of the pump, but these are not detailed in the provided source material.
Ten Golden Rules for Correct Installation
The documentation outlines ten golden rules for correct installation, with only one explicitly stated in the provided source material: All horizontal pipes should have a minimum fall of 1:100. The remaining rules are not detailed within the provided documentation.
Venting Considerations
Venting is an important aspect of macerator pump installation. Where possible, venting should adhere to common plumbing practices and relevant Australian Standards (AS 3500 10:10 & 6:7:4). The documentation does not provide specific details regarding venting requirements beyond this general guidance.
Domestic Use Restriction
The documentation explicitly states that the macerator pump is intended for domestic use only. This restriction should be observed to ensure proper operation and prevent potential damage or safety hazards.
Conclusion
The Thetford Sani-Con 600 Series and similar macerator pumps offer a solution for managing sewage waste in domestic applications. Proper installation is critical, requiring direct coupling to the WC pan spigot, level placement with incoming fixtures, adherence to pipe fall and material specifications, and appropriate venting. The unit is designed for use with standard P-trap WC pans, showers, vanities, and bidets, and is restricted to domestic applications only. Following the provided guidelines will contribute to reliable and efficient operation.
Sources
- Mobile Must Have - Thetford Sani-Con 600 Series Installation Guide
- ManualsLib - Saniflo Macerator Pump