The Knoll Reff Profiles wall mount height adjustable table, reference number 6TP00587, is an electrically powered desk designed for installation on suitable wall structures. This article details the installation instructions, safety precautions, component lists, and system configuration information based on the provided documentation. The table requires careful installation and adherence to safety guidelines to mitigate risks of electrical shock, injury, or damage to the wall structure. The documentation emphasizes the importance of verifying wall suitability and proper fastener usage.

Safety Precautions and Warnings

The provided installation instruction manual highlights several critical safety warnings. A primary concern is the risk of electric shock, injury, or death resulting from improper usage, abuse, or misuse of the electrical components, including the power supply, handset, and motors. Users must read and save the provided safety instructions before operating the table.

The documentation explicitly states the table must only be operated in an upright position and never while inverted. Overloading the table is also a safety hazard; the maximum allowable load is specified on the power supply label. Before moving or servicing the furnishing, all power supply cords must be unplugged to prevent electrical shock.

Table Components and Part Lists

The installation process involves assembling and attaching various components. Several part lists are included in the documentation, detailing the necessary hardware. These include:

  • 1x1x3 L-bracket
  • #10 x ¾” Pan Head Wood Screw (BB)
  • Multi-Clip (CC)
  • #8 x 1” Flat Head Wood Screw (EE)
  • Mid Gable (V) – 5340110
  • 5112220
  • 6TR41189
  • 5114120
  • 6TP13324
  • Notched Top (I) – varies per width
  • Rear Brace (S)
  • #10 x ¾” Pan Head Wood Screw (Z)
  • Disc Plate (Front edge)
  • Leg Top Bracket (FF) – 7061140
  • Leg Top Inside Bracket (GG) – 6TP42170
  • #10 x 7/8 Tek Screw (HH)
  • 1/4-20 x 3” UNC Button Head Cap Screw (P)
  • Width Adjustment Set Screw (D) – 3AE4050
  • #14 x 7/8” Pan Head Wood Screw (R) – 5122218

The documentation notes that the notched top and rear brace dimensions vary depending on the table width.

Installation Procedure Overview

The installation process is divided into several stages, beginning with base assembly and culminating in electrification and work surface attachment. The documentation references an official assembly instruction set found with the base components, advising users to request an approved combination of desktop and frame from their vendor.

Key steps include:

  1. Construct Base Assembly: Detailed instructions for this stage are located with the base components themselves.
  2. Assemble Notched Top and Attach Bracketry: This involves attaching the notched top and associated brackets.
  3. Prepare and Attach Gables: This step includes preparing and attaching the end gables and, if applicable, the mid gable for tables 72 inches or wider.
  4. Wall Mounting: The documentation emphasizes the customer’s responsibility, along with their structural engineers or architects, to verify that the wall structure is capable of supporting the table’s weight plus an additional 3 lbs per linear inch for each usable shelf length.
  5. Electrify Base: This involves connecting the handset to the motor or bus cable socket. Part numbers KR3AF4102 and KR3AF4103 are referenced for the handset connection.
  6. Install Worksurface Top: The work surface top is then installed onto the assembled base.
  7. Affix Handset: The final step involves attaching the handset.

System Configuration and Adjustments

The table features a system configuration that includes a power supply, bus cable, and handset. The documentation provides an example configuration diagram. The table control, handset, and motors are sealed units and do not contain user-serviceable parts. Any adjustments, maintenance, or repairs should be performed by a qualified technician or through the vendor.

Electrical Considerations and Safety

The power supply for the Knoll Reff Profiles table has the following specifications:

  • Input: 120VAC 3.2A 60Hz
  • Output: DC35V
  • Duty Cycle: 1min on/ 9min off

The power supply conforms to ULSTD962 ED.4 and is certified to CAN/CSA STDC22.2 No. 68 2009.

When disconnecting electrical components (power supply, bus cable, or handset), the documentation stresses the importance of pressing the strain relief hook before removing the connector. An audible “click” should be heard when inserting the connector.

Wall Mounting Guidelines and Structural Integrity

The documentation places significant emphasis on the structural integrity of the wall to which the table is mounted. It is the responsibility of the customer and their structural engineers/architects to ensure the wall can support the table’s weight, plus an additional load of 3 lbs per linear inch of usable shelf length.

The installation process involves fastening the rear brace and end gables to the wall using appropriate customer-supplied fasteners. The documentation advises replacing drywall and repairing as needed after fastener installation. Knoll does not assume responsibility for the installation, attachment, or securing of fasteners.

Important Notices and Disclaimers

Knoll reserves the right to discontinue or change specifications or design at any time without notice or obligation. The information and specifications included in the manual were accurate at the time of printing.

Conclusion

The Knoll Reff Profiles wall mount height adjustable table requires careful installation and adherence to safety guidelines. The documentation stresses the importance of verifying wall structural integrity, using appropriate fasteners, and following electrical safety precautions. The table’s sealed electrical components require professional servicing, and users should contact their vendor or a qualified technician for any maintenance or repairs. Proper installation and operation will ensure the safe and reliable use of this height-adjustable desk.

Sources

  1. Knoll Reff Profiles 6TP00587 Installation Instruction
  2. Knoll Reff Profiles 6TP00587 Mount Table

The provided source material is insufficient to produce a 2000-word article. Below is a factual summary based on available data.

Previous post: Knoll Interpole: System Furniture Design and Technical Overview

Next Post: KnoxBox 3200 & KnoxVault 4400 Electrical Switch Installation and Operation

Related Posts