The Iron-A-Way ironing center requires careful installation to ensure safe and effective operation. This article details the installation procedures for both recessed and surface mount configurations, as outlined in the provided documentation. It also covers necessary supplies and electrical connection considerations. The documentation specifies models including AE-46, ANE-46, AE-42, ANE-42, UD-42, A-42, A-46, IAW-42, and NE-242.
Pre-Installation Considerations
Prior to commencing installation, several preparatory steps are recommended. The documentation emphasizes the importance of locating existing wiring or utilities within the intended installation wall to prevent accidental damage during drilling. Adequate clearance for ironing is also crucial; the door opens approximately 180 degrees, necessitating at least 16 inches of side clearance for unobstructed operation.
The documentation differentiates between swivel and non-swivel models, impacting screw requirements. Swivel models include AE-46, ANE-46, AE-42, ANE-42, and UD-42, while non-swivel models are IAW-42, NE-46, E-42, and NE-42.
Required Supplies
Successful installation requires both supplied parts and additional materials procured by the installer. The Iron-A-Way unit itself is listed as a required component.
Supplied Parts:
- #10 x 1 1/2” Wood Screws (for recessed installation – quantity varies by model)
- #14 x 2 1/2” Phillips Screws (for recessed installation – quantity varies by model)
- #14 x 4” Wood Screws (for surface mount installation – quantity varies by model)
Supplies Needed (not included):
- Carpenter’s Level
- Tape Measure
- Utility Knife
- Drill
- 1/8” Drill Bit
- 3/16” Drill Bit (specifically for surface mount installation)
- Small Flat Head Screwdriver
- Safety Glasses
- 2 x 4 Cross Support Cleat (for recessed installation)
- 2 x 4 Brace (for surface mount installation)
- Optional: Stud Finder
- Optional: 1/4” Nut Driver
Recessed Mount Installation
The documentation details specific screw requirements for recessed installation, varying based on whether the model is a swivel or non-swivel type.
Screw Requirements (Recessed Mount):
- Swivel Models: #10 x 1 1/2” Wood Screws (4)
- Non-Swivel Models: #10 x 1 1/2” Wood Screws (4)
- IAW-42 Only: #14 x 2 1/2” Wood Screws (2)
The documentation references pages 3 and 5 as containing detailed instructions for recessed mounting, depending on the model type. The use of a 2 x 4 Cross Support Cleat is specifically noted as necessary for recessed installations.
Surface Mount Installation
Surface mount installation also requires specific screw types. The documentation specifies the use of #14 x 4” Wood Screws (2) for both swivel and non-swivel models. The documentation references pages 4 and 6 for detailed surface mount installation instructions, again differentiating based on model type. A 2 x 4 Brace is required for surface mount installations. A 3/16” drill bit is specifically mentioned as necessary for surface mount installation.
Electrical Connections
Electrical connection is a critical aspect of the installation process. The documentation instructs users to connect all power supply wires and ground wires in accordance with all applicable electrical codes. Excess supply wire should be trimmed after connection.
A specific note is provided for models A-46 and AL-42: inside the front cover of the electrical wireway, a yellow label identifies the Electrical Supply Connection Area. The documentation emphasizes that wire nuts must be placed and secured within this designated area, as indicated by the yellow tag. The documentation references page 7 for detailed electrical information.
Model-Specific Screw Charts
The following table summarizes the screw requirements based on the Iron-A-Way model and installation type:
| Model | Installation Type | Screw Type & Quantity |
|---|---|---|
| AE-46 | Recessed | #10 x 1 1/2” Wood Screws (4) |
| AE-46 | Surface Mount | #14 x 4” Wood Screws (2) |
| ANE-46 | Recessed | #10 x 1 1/2” Wood Screws (4) |
| ANE-46 | Surface Mount | #14 x 4” Wood Screws (2) |
| AE-42 | Recessed | #10 x 1 1/2” Wood Screws (4) |
| AE-42 | Surface Mount | #14 x 4” Wood Screws (2) |
| ANE-42 | Recessed | #10 x 1 1/2” Wood Screws (4) |
| ANE-42 | Surface Mount | #14 x 4” Wood Screws (2) |
| UD-42 | Recessed | #10 x 1 1/2” Wood Screws (4) |
| UD-42 | Surface Mount | #14 x 4” Wood Screws (2) |
| IAW-42 | Recessed | #14 x 2 1/2” Wood Screws (2) |
| IAW-42 | Surface Mount | #14 x 4” Wood Screws (2) |
| NE-46 | Recessed | #10 x 1 1/2” Wood Screws (4) |
| NE-46 | Surface Mount | #14 x 4” Wood Screws (2) |
| E-42 | Recessed | #10 x 1 1/2” Wood Screws (4) |
| E-42 | Surface Mount | #14 x 4” Wood Screws (2) |
| NE-42 | Recessed | #10 x 1 1/2” Wood Screws (4) |
| NE-42 | Surface Mount | #14 x 4” Wood Screws (2) |
Safety Precautions
The documentation explicitly lists safety glasses as a required supply, indicating the importance of eye protection during installation. General safety practices related to drilling and electrical work should also be observed.
Conclusion
Proper installation of the Iron-A-Way ironing center is essential for safe and reliable operation. The documentation provides detailed instructions for both recessed and surface mount configurations, with specific screw requirements varying by model. Careful attention to electrical connections, particularly for models A-46 and AL-42, is crucial. Adherence to the provided guidelines and the use of appropriate safety measures will ensure a successful installation.