The Hydro Systems Metro Collection bathtub requires adherence to specific installation procedures and safety precautions. Documentation emphasizes thorough inspection for damage, compliance with local codes, and proper electrical grounding. User maintenance involves regular cleaning with mild detergents and avoidance of abrasive cleaners to preserve the tub’s finish. A critical step in the installation process is a 30-minute water test to identify potential leaks before enclosure. The documentation also includes a warning regarding potential exposure to chemicals, specifically styrene.
Installation Procedures
Installation of a Hydro Systems Metro Collection bathtub necessitates careful attention to detail and adherence to applicable codes and regulations. The documentation stresses the importance of a pre-installation inspection. Users are instructed to examine the tub for any damage or defects before beginning the installation process. Should any issues be identified, installation should be halted, and technical support contacted at 661-775-0686 or via email at [email protected]. Installation should not proceed if the tub is the incorrect size, model, or color.
The documentation highlights that all tubs and systems undergo rigorous testing and inspection at the factory. However, damage can occur during shipping and installation, which may not always be immediately apparent. To maintain warranty coverage, a water test of the tub, integral overflow, and thermal system is required for a minimum of 30 minutes to check for leaks before the tub is enclosed. Hydro Systems explicitly states it is not responsible for the costs associated with removing or reinstalling a tub.
Electrical installation requires specific attention to grounding. A green-colored terminal marked “Ground” is provided on the exterior of the control box. This terminal must be connected to the grounding terminal of the electrical service or supply panel using a conductor of equivalent size to the circuit conductors supplying the equipment. The documentation also emphasizes the importance of verifying proper GFCI (Ground Fault Circuit Interrupter) operation before using the whirlpool tub.
Safety Precautions
Several safety precautions are outlined in the provided documentation. A general warning states that when using a Hydro Systems tub, basic safety precautions should always be followed. A specific danger warning advises against allowing children to use the unit without close supervision at all times.
The unit should only be used for its intended purpose, as described in the manual. The use of attachments not recommended by the manufacturer is prohibited. Users are cautioned never to drop or insert any objects into any openings in the tub or its associated systems.
A California Proposition 65 warning is included, stating that the product can expose users to chemicals, including styrene, which is known to the State of California to cause cancer. Users are directed to www.P65Warnings.ca.gov for further information.
Care and Cleaning
Maintaining the appearance of a Hydro Systems Metro Collection bathtub requires regular care and cleaning. The documentation recommends cleaning with a soft cloth or sponge and a mild soap or liquid detergent for normal maintenance, particularly after each use.
The use of abrasive cleaning agents is strictly prohibited. Specifically, users should avoid scouring compounds, scouring pads, steel wool, and harsh chemicals. For more stubborn stains or hard scale deposits, or for any other cleaning or maintenance issues, contacting a Hydro Systems dealer is advised. These procedures are intended to help maintain a “like new” appearance for an extended period.
Warranty Considerations
The documentation emphasizes the importance of the 30-minute water test during rough inspection to maintain warranty coverage. Damage occurring during shipment or installation, if not detected and addressed before enclosure, may not be covered under warranty. Hydro Systems is not responsible for the expenses incurred in removing and reinstalling a tub if issues are discovered after enclosure without prior water testing.
Electrical Requirements
Proper electrical connection is crucial for safe operation. The documentation specifies the need for a grounding connection using the provided green terminal. The grounding conductor must be of a size equivalent to the circuit conductors supplying the equipment. Furthermore, the documentation stresses that the whirlpool tub should only be used when the GFCI is functioning correctly.
Potential Chemical Exposure
The documentation includes a warning regarding potential exposure to chemicals, specifically styrene, which is identified as a substance known to the State of California to cause cancer. This warning directs users to the website www.P65Warnings.ca.gov for additional information.
Conclusion
The installation of a Hydro Systems Metro Collection bathtub requires careful adherence to provided instructions, with a strong emphasis on pre-installation inspection, proper electrical grounding, and a thorough water test before enclosure. Regular maintenance using mild cleaning agents and avoiding abrasives will help preserve the tub’s finish. Users should be aware of the safety precautions outlined in the documentation, including the warning regarding potential exposure to styrene. Following these guidelines will ensure safe operation and maintain warranty coverage.