The Framery Six and Framery One smart meeting rooms and phone booths are designed to provide acoustically isolated, technologically advanced environments for professional and personal use. These modular, indoor-only spaces integrate smart features, adjustable components, and energy-efficient design while requiring careful installation and adherence to safety guidelines. This article provides a detailed overview of installation best practices, safety precautions, and technical specifications for U.S. users based on Framery’s official documentation.
Overview of Framery Pod Models and Features
The Framery product line includes two primary models: the Framery Six and the Framery One. The Framery Six is a smart meeting room designed for up to six individuals, offering sound-insulated walls, adjustable tables, and integrated control systems. The Framery One is a smaller, single-occupant phone booth with high-gloss black frames made from steel and aluminum and laminated sound control glass. Both models are intended for short-term, indoor use and are engineered to provide high acoustic performance and minimal space consumption.
Technical specifications for power input and output are clearly outlined in the product labels. The Framery Six and related components use 24V DC power for internal operation, with the control unit, radar unit, and power unit having specific input and output requirements. For U.S. and Canadian use, the manufacturer specifies the use of SJT type 16 AWG cords to mitigate fire and shock hazards.
Installation Considerations and Requirements
Installation of a Framery pod requires a careful assessment of the intended location, ambient conditions, and access to electrical infrastructure. The manufacturer emphasizes the importance of using the optional casters for mobility, as moving the pod without them requires significant force. A risk assessment must be conducted on-site prior to any physical movement or installation activity.
According to the Framery Six installation instructions, the pod must be installed in an indoor environment with the following conditions: - Ambient temperature: +15°C to +30°C (59°F to 86°F) - Humidity: Maximum 50% - Air quality: Sufficient for safe operation
The installation process must also comply with local safety regulations, and users are required to read and understand all instructions before beginning work. Safety equipment, such as cut-resistant gloves, steel-toed boots, and safety glasses, is recommended to prevent injury during installation or maintenance.
Safety Precautions During Installation and Use
Safety is a central focus in the Framery product documentation, with several warnings and guidelines outlined to ensure user protection. The following precautions are emphasized:
Electrical Safety: The Framery Six and associated units operate on 100-240 VAC (50-60 Hz) and 24V DC power. Users must ensure that the product is connected to a grounded socket to prevent fire or electric shock hazards. For U.S. and Canadian markets, only SJT type 16 AWG cords are approved for use.
Load and Weight Restrictions: The maximum load for the Framery Six is 65 lbs (30 kg), and the table has a maximum load capacity of 131 lbs (60 kg). Users must avoid exceeding these limits to prevent structural or mechanical failure.
Ventilation and Air Quality: The Framery pod relies on ambient air for internal ventilation. Users must ensure that the ventilation channels are unobstructed, free of lint, hair, or debris. The pod must not be used if the ventilation system is malfunctioning or if the surrounding air quality is unsafe.
Prohibited Uses: The manufacturer explicitly states that the pod is not to be used outdoors, with alterations, beyond the intended load capacity, or in the presence of obvious defects. Climbing on the roof, placing objects on the pod, or smoking inside is strictly prohibited.
Children and Vulnerable Individuals: The Framery Six must be supervised closely when used by children, invalids, or disabled individuals. The footrest and table mechanisms pose injury risks if not used with care. Users are advised to keep children away from moving or adjustable parts and to ensure that all safety warnings are clearly communicated.
Electrical Equipment and Maintenance: If any defects are observed in the electrical components or if the pod is not functioning properly, the power cord must be disconnected immediately, and the user should contact the manufacturer or an authorized dealer for assistance.
Technical Specifications and Compliance
Framery’s technical documentation provides detailed specifications for the electrical components of the Framery Six and Framery One. The Framery Core Unit has the following specifications: - Input: 24V DC - Output: 24V DC (xA MAX), 5V DC (xA MAX) - Model: 9005682
The Framery Radar Unit is designed to support the smart features of the meeting room, with the following specifications: - Input: 24V DC (2.2A MAX) - Output: 24V DC (1.8A MAX) - Model: 9007966
For U.S. compliance, the product is labeled with FCC IDs and IC numbers, including: - FCC ID: 2AX4J9005682 - IC: 26702-9005682 - FCC ID: 2AX4J9007966 - IC: 26702-9007966
These identifiers confirm that the device is in compliance with U.S. Federal Communications Commission (FCC) regulations. Additionally, the product has received NTC type approval (ESD-GEC-2106829) and Korean KC certification (R-CS-Fr4-9000456), further reinforcing its regulatory compliance in multiple international markets.
Maintenance and Troubleshooting
The Framery documentation includes a section on troubleshooting and maintenance procedures. Users are advised to keep the work area clean and to follow all local safety regulations during any maintenance activity. If the pod is not operating correctly, the first step is to disconnect the power supply and inspect for visible signs of damage or malfunction.
Common issues that may arise include: - Malfunctioning adjustable table – Users should avoid placing hands or body parts near the table edges when it is in motion. - Blocked ventilation – Ensure that the internal and external ventilation channels are free of obstructions. - Electrical faults – If the control unit or power unit shows signs of damage, users should contact Framery or an authorized dealer immediately.
The manufacturer also emphasizes that any modifications or disassembly not approved by Framery Oy could void the user’s operating authority, and professional assistance should be sought for complex repairs.
Environmental and Regulatory Compliance
Framery’s documentation highlights the importance of adhering to environmental and regulatory standards during installation and use. The pod must not be used in locations where the temperature or air quality is outside the specified limits, and users must ensure that the product is not exposed to extreme conditions. The manufacturer also provides compliance documentation that includes ANSI Z97.1-2015 and 16 CFR 1201 Part II certifications, which are relevant for safety and performance standards in the U.S. market.
For installation in the United States and Canada, Framery provides installation and maintenance instructions that must be followed strictly. These instructions are designed to ensure that the product operates safely and efficiently under all expected conditions.
Conclusion
The Framery Six and Framery One smart meeting rooms and phone booths are advanced, acoustically engineered solutions for modern workspaces. Their installation requires careful planning, adherence to safety protocols, and compliance with technical specifications. Users must ensure that the products are installed in appropriate indoor environments, connected to the correct power sources, and maintained according to manufacturer guidelines. By following the detailed instructions and safety precautions outlined in Framery’s documentation, users can maximize the performance and longevity of their pods while minimizing risks to themselves and others.