Framery Six is a modular smart meeting room designed for short-term indoor commercial and household use, accommodating up to six individuals at a time. As a product of Framery Oy, a Finnish manufacturer specializing in soundproof private spaces, the Framery Six integrates advanced features such as adjustable tables and intelligent climate control systems. Installation and operation of the Framery Six must be performed with strict adherence to safety protocols and environmental specifications. This article provides a detailed overview of the installation process, safety precautions, and technical specifications based on the Framery Six 9007966 Smart Meeting Room instruction manual and additional product information provided by the manufacturer.

Understanding Framery Six and Its Intended Use

The Framery Six is designed for indoor use and is not suitable for outdoor deployment. It is recommended for commercial and household environments where privacy and acoustics are important. The product is intended for use by one to six individuals at a time, and it is not recommended for locations where children are likely to be present due to the risk of injury from moving or adjustable parts. Users must ensure the product is installed in a location with a stable and safe ambient environment, including a temperature range of +15°C to +30°C (59°F to 86°F) and a maximum humidity of 50%.

The Framery Six incorporates an electrically adjustable table, which requires users to be cautious when raising or lowering the table surface. The manual emphasizes that close supervision is necessary when the product is used by or near children, invalids, or disabled persons. Furthermore, the manual warns against placing any load on the roof of the product and prohibits climbing on top of it.

Safety Precautions for Installation and Maintenance

Installation and maintenance of the Framery Six must be conducted with appropriate safety measures. The manual provides specific guidance on the use of personal protective equipment (PPE) during installation. Users are advised to wear cut-resistant safety gloves, steel-toed safety boots, and safety glasses to minimize the risk of injury during handling and assembly.

Prior to beginning any installation or maintenance work, it is essential to read and understand all instructions provided in the manual. Adherence to local safety regulations is mandatory, and users should ensure that the work area is clean and free from hazards. A risk assessment should be conducted before attempting to move the product without the optional casters, as this requires significant force and may pose a risk to personnel.

The manual also outlines several prohibited actions, including the use of the product outdoors, the installation of the product without reading the instructions, and the use of non-recommended attachments. Any alterations or modifications to the product are strictly prohibited, as they may compromise the structural integrity and safety of the unit.

Electrical and Power Requirements

The Framery Six requires a stable electrical supply for operation. The power unit is designed to operate with an input of 100-240 VAC at 50-60 Hz, with a maximum current draw of 10A. The power unit provides a low-power supply (LPS) output of 24V DC at 4A and a general supply transformer (GST) output of 100-240 VAC at 9A maximum. The output for the core unit is 24V DC at up to 4A, and for the radar unit, it is 24V DC at 1.8A maximum.

The manual emphasizes the importance of using the correct type of power cord. For use in the United States and Canada, only an SJT type 16 AWG cord should be used to minimize the risk of fire and electric shock. Users are advised to ensure that the product is always connected to a grounded socket to avoid electrical hazards. Any defects in the electrical equipment must be addressed immediately by disconnecting the power and contacting the manufacturer.

Technical Specifications and Label Information

The Framery Six includes several technical labels and markings that provide important information about the product's compliance and safety certifications. These labels are located on various components of the unit and must be reviewed for proper identification and compliance.

For example, the Framery Core Unit is labeled with the model number 9005682 and includes an FCC ID of 2AX4J9005682. The Framery Radar Unit is labeled with the model number 9007966 and an FCC ID of 2AX4J9007966. These labels also include other regulatory certifications such as the NTC Type Approved No. ESD-GEC-2106829 and KC ID R-CS-Fr4-9000456.

Additional labels include warnings about the maximum load capacity of the product, such as the maximum load of 65 lbs (30 kg) and the maximum table load of 131 lbs (60 kg). Users are advised to adhere to these load limits to prevent structural failure or injury.

Environmental and Ventilation Requirements

The Framery Six is designed for use in environments with sufficient air quality. The product relies on the surrounding air for internal ventilation, and users must ensure that the ventilation channels are not blocked. Blockage of these channels can lead to overheating or malfunction of the internal components. Users should regularly check for lint, hair, and other obstructions that may compromise the airflow.

The manual also warns against using the product in hazardous conditions, such as areas with poor air quality or where the ventilation system is not functioning properly. If the ventilation is not working, the product should not be used until the issue is resolved. The internal air circulation is derived from the surrounding space, and any defects in the ventilation system may pose a risk to the health and safety of users.

Troubleshooting and Maintenance

The Framery Six manual includes troubleshooting guidance for common issues that may arise during operation. For example, if the ventilation system is not functioning, users should check for blockages in the ventilation channels and ensure that the air quality is adequate. If the electrical equipment is not working properly, users should immediately disconnect the power supply and contact the manufacturer or an authorized dealer.

The manual also emphasizes the importance of not using the product if any defects are noticed, such as damaged electrical components or malfunctioning features. In such cases, the product must be disconnected and inspected by a qualified technician.

Regulatory Compliance and FCC Information

The Framery Six is compliant with several regulatory standards, including FCC regulations for radio frequency devices. The control unit of the Framery Six is a portable device that must be used exclusively within the Framery pod and is not to be integrated into any other device. The FCC labeling and compliance information is accessible through the control unit's display, and users are advised to review this information to ensure compliance with local regulations.

The manual also notes that any changes or modifications not expressly approved by Framery Oy may void the user’s authority to operate the equipment. Users are advised to consult with an authorized dealer or a qualified technician for assistance with any modifications or troubleshooting.

Conclusion

The Framery Six is a sophisticated smart meeting room designed for indoor use, offering advanced features such as adjustable tables and intelligent climate control. Installation and operation must be performed with strict adherence to safety protocols and environmental specifications. Users are advised to follow the manufacturer's guidelines for installation, maintenance, and troubleshooting to ensure the product functions correctly and safely.

The Framery Six manual provides comprehensive guidance on the use of personal protective equipment, electrical requirements, and regulatory compliance. Users must ensure that the product is installed in a location with a stable and safe ambient environment, and any defects or malfunctions must be addressed immediately to prevent risk of injury or damage.

Sources

  1. Framery Six 9007966 Smart Meeting Room Manual
  2. Framery Official Product Page

Previous post: Framery Four Installation Instructions and Safety Guidelines for U.S. Users

Next Post: Framery Pod Installation and Safety Guidelines for U.S. Users