The Falcon product line, a division of Schlage, offers a range of mortise locks designed for commercial and high-security applications. These locks are commonly used in institutional settings such as schools, hospitals, and corporate offices due to their robust construction and customizable features. This article provides an in-depth review of installation and trim configuration instructions for Falcon mortise locks and related components, based on official technical documentation provided by Schlage.
Installation procedures for Falcon mortise locks vary depending on the specific model and trim configuration. The documentation includes detailed instructions for mounting plates, lever trims, anti-ligature options, and electrified functions. The following sections explore key aspects of these installation processes, including mechanical and electrified lock types, trim variations, and special features such as key override and coin cell battery replacement.
Installation Overview for Falcon Mortise Locks
The Falcon mortise lock family includes several series, including the L9000, LM9200, and ND-series models. Each series has distinct installation requirements, primarily dictated by the type of lock mechanism and trim options selected. The installation process generally involves the following steps:
Preparation and Measurement: Before installing a mortise lock, it is essential to measure the door thickness and ensure compatibility with the lock body. The mortise cavity must be properly prepared to accommodate the lock mechanism, including space for the strike plate and any indicator components.
Mounting Plate Installation: Most Falcon mortise locks require a mounting plate to secure the lock body to the door. The mounting plate is typically attached using screws or bolts, depending on the model. For example, the L9000 series uses a mounting plate that is secured with the lock body inside the mortise cavity.
Trim Assembly: The trim assembly includes the lever or knob, escutcheon, and any indicator components. The trim is mounted to the lock body using screws or other fasteners. The trim can be configured for lever-only, knob-only, or lever and knob combinations, depending on the model and application.
Electrified Function Installation: For electrified models such as the L9000 series with indicator, additional wiring and configuration steps are required. This includes connecting the lock to an electrical power source and configuring the indicator settings.
Testing and Adjustment: After installation, it is important to test the lock to ensure proper operation. This includes verifying that the lock engages and disengages correctly and that any electrified functions operate as expected.
L9000 Series Installation Details
The L9000 series is one of the most widely used Falcon mortise lock lines, particularly for applications requiring anti-ligature features. The installation instructions for this series are detailed in several documents, including "Schlage L9000 Series Lock with Indicator Sectional Trim Installation Instructions" and "Schlage L-Series Anti-Ligature Lever Trim Installation Instructions."
Anti-Ligature Features
Anti-ligature designs are critical in institutional settings where safety is a priority. The L9000 series includes anti-ligature lever and knob trims, which prevent the use of the lock components for self-harm. These trims are designed to eliminate any protrusions or gaps that could be used for ligature purposes. The anti-ligature lever trim (SL1) and anti-ligature knob trim (SK1) are installed using the same mounting plate as standard lever and knob trims.
Indicator and Escutcheon Installation
The L9000 series with indicator includes a visual indicator that shows whether the lock is engaged or disengaged. The indicator is typically located on the door surface and is connected to the lock body via a cable or mechanical linkage. The installation instructions for the indicator include steps for routing the cable, attaching the indicator to the door, and adjusting the indicator position to ensure visibility.
The escutcheon is a decorative plate that covers the area around the lock and trim. For the L9000 series, the escutcheon is installed after the trim is in place. The escutcheon is typically secured using screws or clips, depending on the model.
LM9200 Series Installation
The LM9200 series is another line of Falcon mortise locks that includes a range of lever configurations. The installation instructions for this series are outlined in "Schlage LM9200 Series Lock Installation Instructions." This series is primarily mechanical and does not include electrified functions. The installation process is similar to the L9000 series, with the following key steps:
Mounting Plate Installation: The LM9200 series requires a mounting plate to secure the lock body to the door. The mounting plate is typically attached using screws or bolts.
Trim Installation: The trim assembly includes lever trims, which can be configured as single or double dummy levers. The installation instructions include steps for attaching the lever trims to the lock body and adjusting the lever height to ensure proper operation.
Strike Plate Installation: The strike plate is installed on the door frame and must be aligned with the lock mechanism. The strike plate is typically secured using screws and adjusted to ensure smooth operation of the lock.
ND-Series Installation and Electrified Functions
The ND-series includes both mechanical and electrified lock options. The installation instructions for this series are outlined in several documents, including "Schlage ND Series Timing Guide" and "Schlage ND Series Electrified Functions Old Version (Manufactured before 3-14-2016) Installation Instructions."
Mechanical Installation
For mechanical ND-series locks, the installation process involves the following steps:
Mounting Plate Installation: The ND-series requires a mounting plate to secure the lock body to the door. The mounting plate is typically attached using screws or bolts.
Trim Installation: The trim assembly includes lever or knob trims, which can be configured as single or double dummy trims. The installation instructions include steps for attaching the trim to the lock body and adjusting the trim height to ensure proper operation.
Strike Plate Installation: The strike plate is installed on the door frame and must be aligned with the lock mechanism. The strike plate is typically secured using screws and adjusted to ensure smooth operation of the lock.
Electrified Functions
For electrified ND-series locks, additional wiring and configuration steps are required. The installation instructions include steps for connecting the lock to an electrical power source and configuring the lock’s functions. For example, the ND25 model includes a key override feature that allows the lock to be disengaged using a physical key, even when the lock is in an electrified state.
Special Features and Accessories
Several special features and accessories are available for Falcon mortise locks, including anti-ligature trims, indicator trims, and electrified functions. These features are outlined in the following sections:
Anti-Ligature Trims
Anti-ligature trims are designed to prevent the use of the lock components for self-harm. These trims are available for both lever and knob configurations and are installed using the same mounting plate as standard trims. The installation instructions for anti-ligature trims include steps for attaching the trim to the lock body and adjusting the trim to ensure proper operation.
Indicator Trims
Indicator trims provide a visual indication of whether the lock is engaged or disengaged. These trims are typically used in high-security applications where it is important to know the status of the lock at a glance. The installation instructions for indicator trims include steps for routing the indicator cable, attaching the indicator to the door, and adjusting the indicator position to ensure visibility.
Electrified Functions
Electrified functions allow the lock to be controlled remotely using an electrical signal. These functions are available on several Falcon mortise lock models, including the L9000 and ND25 series. The installation instructions for electrified functions include steps for connecting the lock to an electrical power source, configuring the lock’s functions, and testing the lock to ensure proper operation.
Installation Considerations
Several considerations should be taken into account when installing Falcon mortise locks. These include the following:
Door Thickness: The mortise cavity must be properly prepared to accommodate the lock mechanism. The door thickness must be compatible with the lock body and any indicator components.
Trim Configuration: The trim configuration must be selected based on the application. Lever-only, knob-only, and lever and knob configurations are available for different models.
Electrified Functions: If electrified functions are required, the lock must be connected to an electrical power source and configured properly. This includes routing the wiring, configuring the lock’s functions, and testing the lock to ensure proper operation.
Anti-Ligature Features: If anti-ligature features are required, the appropriate trims must be selected and installed. These trims are designed to prevent the use of the lock components for self-harm.
Testing and Adjustment: After installation, it is important to test the lock to ensure proper operation. This includes verifying that the lock engages and disengages correctly and that any electrified functions operate as expected.
Conclusion
Falcon mortise locks are designed for high-security applications and require careful installation to ensure proper operation. The installation process involves several steps, including preparing the door, installing the mounting plate, assembling the trim, and configuring any electrified functions. The documentation provided by Schlage includes detailed instructions for each step of the installation process, ensuring that users can install the lock correctly and safely.
Special features such as anti-ligature trims, indicator trims, and electrified functions are available for different models and must be selected based on the application. These features enhance the security and functionality of the lock, making them ideal for institutional and commercial settings.
By following the installation instructions provided in the official documentation, users can ensure that the lock is installed correctly and operates as intended. This includes testing the lock after installation to verify that it functions properly and meets the required security standards.
Sources
- Schlage L9000 Series Lock with Indicator Sectional Trim Installation Instructions
- Schlage L-Series Anti-Ligature Lever Trim Installation Instructions
- Schlage LM9200 Series Lock Installation Instructions
- Schlage ND Series Timing Guide
- Schlage ND Series Electrified Functions Old Version (Manufactured before 3-14-2016) Installation Instructions
- Schlage ND25 Installation Instructions (locks manufactured after 1-31-2017)