Introduction
The installation of Arrow mortise locks into Networx Trilogy systems is a highly specialized process requiring attention to detail and adherence to manufacturer specifications. The Arrow S1200/S1250 model, as noted in the provided documentation, is specifically referenced in the context of Networx ETDL and ETPDL systems, indicating the necessity of using the appropriate installation templates and alignment guides.
Based on the source material, Arrow mortise locks are commonly integrated with Networx-based access control systems, particularly in commercial and institutional settings where secure, programmable door control is essential. The process involves not only the physical installation of the lockset but also the configuration of the lock within the broader access control architecture, including compatibility with specific exit devices, door hardware, and firmware updates.
The documentation includes installation templates, programming instructions, and compatibility notes with other hardware such as the Arrow S1200/S1250 model. These materials are sourced from official technical manuals and firmware updates provided by Alarm Lock, ensuring that the installation process is conducted according to the highest industry standards.
This article provides a detailed overview of the installation process, including necessary tools, hardware compatibility, and step-by-step instructions for proper installation and configuration.
Overview of Networx Trilogy Systems and Arrow Mortise Locks
Networx Trilogy systems are programmable access control solutions designed for commercial and institutional environments. These systems support a wide range of lock types, including mortise locks, which are commonly used in commercial doors due to their durability and secure design. The Arrow S1200/S1250 model is a specific type of mortise lock that is compatible with Networx Trilogy systems, as outlined in the provided documentation.
Arrow mortise locks are known for their robust construction and compatibility with various door hardware configurations. The documentation highlights the use of specific installation templates for Arrow mortise locks in Networx ETDL and ETPDL systems. These templates ensure that the lock is properly aligned with the door and strike plate, which is crucial for both functionality and security.
The Networx Trilogy systems support multiple lock models, including the DL1200ET, DL1300ET, and PDL1300ET, which are also compatible with Arrow mortise locks. This compatibility is documented in the installation templates provided by Alarm Lock, ensuring that users can integrate Arrow mortise locks into their access control systems without issues.
Programming is another essential aspect of the installation process. The documentation includes programming instructions for various models, including the DL1200ET, DL1300ET, and PDL1300ET, which are relevant to the installation of Arrow mortise locks. These instructions outline how to configure the lock for different functions, such as access levels, entry/exit modes, and alarm settings.
Firmware updates are also an important consideration when installing Arrow mortise locks in Networx Trilogy systems. The documentation references specific firmware versions for different lock models, ensuring that the locks operate optimally within the system.
Installation Templates for Arrow Mortise Locks
The installation of Arrow mortise locks in Networx Trilogy systems requires the use of specific installation templates to ensure proper alignment and functionality. The documentation references a template for the DL1200ET, DL1300ET, and PDL1300ET models when installed with the Arrow S1200/S1250 model. These templates are designed to mark the necessary positions on the door and frame for the lock components.
The installation process begins with the selection of the appropriate template based on the lock model and door type. The template is then placed on the door, and the necessary holes for the lock cylinder, lever, and strike plate are marked. These marks are transferred to the door using a pencil or marking tool, and the holes are drilled or cut accordingly.
The installation template also includes instructions for positioning the strike plate on the door frame. The strike plate must be aligned with the latch or deadbolt of the lock to ensure smooth operation. In some cases, adjustments may be necessary if the door or frame does not align perfectly with the template.
Once the holes and strike plate position are marked, the lock components can be installed. The mortise box is inserted into the prepared hole, and the lock mechanism is secured in place using screws or other fasteners. The lever and cylinder are then installed, and the strike plate is mounted on the door frame.
The documentation also references additional installation templates for other lock models, including the DL1225ET, DL1325ET, and PDL1325ET, which are also compatible with Arrow mortise locks. These templates are designed for doors with different configurations, such as narrow stiles or double doors.
It is important to note that the installation process may vary slightly depending on the specific model and application. Therefore, it is recommended to consult the manufacturer's installation instructions for detailed guidance.
Compatibility with Networx Trilogy Systems
Arrow mortise locks are designed to be compatible with a wide range of Networx Trilogy systems, making them suitable for various applications. The documentation outlines the compatibility of Arrow mortise locks with specific models such as the DL1200ET, DL1300ET, and PDL1300ET. These models are part of the Networx Trilogy line and are designed for integration with programmable access control systems.
The compatibility of Arrow mortise locks with Networx Trilogy systems is ensured through the use of standardized installation templates and programming instructions. These templates and instructions are provided by Alarm Lock and are based on industry standards for door hardware. They ensure that the lock is properly aligned with the door and frame and that the programming settings are correctly configured.
Programming is a critical aspect of compatibility, as it determines how the lock functions within the access control system. The documentation includes programming instructions for various models, including the DL1200ET, DL1300ET, and PDL1300ET. These instructions outline how to configure the lock for different functions, such as access levels, entry/exit modes, and alarm settings.
The documentation also references firmware updates for different lock models, ensuring that the locks operate optimally within the system. Firmware updates are important for maintaining the security and functionality of the lock and should be applied according to the manufacturer's recommendations.
In addition to compatibility with specific lock models, Arrow mortise locks are also compatible with various exit devices and door hardware. The documentation references the use of specific exit devices with Networx Trilogy systems, ensuring that the locks can be integrated with a wide range of door configurations.
Programming Instructions for Arrow Mortise Locks
Programming is a crucial step in the installation of Arrow mortise locks in Networx Trilogy systems. The documentation includes programming instructions for various models, including the DL1200ET, DL1300ET, and PDL1300ET. These instructions outline how to configure the lock for different functions, such as access levels, entry/exit modes, and alarm settings.
The programming process typically begins with the use of the DL-Windows software, which is a user interface for configuring Networx Trilogy systems. The software allows users to set up access control parameters, such as user codes, schedules, and alarm settings. The documentation references different versions of DL-Windows, including versions 4.0.1 and 5.0, indicating that the programming process may vary slightly depending on the software version.
The programming instructions also include information on how to set up different lock modes, such as passage mode, which allows the door to remain unlocked for a specified period, and lockout mode, which prevents entry or exit. These modes are important for managing access control in different scenarios and can be configured using the DL-Windows software.
The documentation also includes instructions on how to restore factory settings, which may be necessary if the lock is not functioning correctly. This process involves using the factory master code to reset the lock to its default settings.
In addition to basic programming functions, the documentation also includes instructions for advanced features, such as the use of multiple "one-time-only" user codes. These codes can be used for temporary access, such as for service personnel or visitors.
Programming is an essential part of the installation process, as it determines how the lock functions within the access control system. Therefore, it is important to follow the manufacturer's instructions carefully and to test the lock after programming to ensure that it operates as intended.
Firmware Updates and System Integration
Firmware updates play a vital role in ensuring the optimal performance and security of Arrow mortise locks within Networx Trilogy systems. The provided documentation references several firmware versions for various lock models, including the DL6100, DL6500, and PDL6100. These updates are designed to enhance system compatibility, improve lock functionality, and address potential security vulnerabilities.
The firmware versions are typically applied using the DL-Windows software, which allows users to download and install the latest firmware directly from the manufacturer. The documentation references firmware updates for specific models, such as the DL6500 Networx V58g and the ETPDLN Networx V62g. These versions ensure that the locks operate in accordance with the latest industry standards and are compatible with the broader access control system.
In some cases, firmware updates may be necessary to resolve issues with the lock's performance or to enable new features. For example, the documentation mentions firmware updates for the ETPDNRX Networx V70a and the PDL8600 Networx V79b, which likely include enhancements to the lock's functionality and integration with other system components.
System integration is another important consideration when installing Arrow mortise locks. The documentation references the use of specific exit devices and door hardware with Networx Trilogy systems, ensuring that the locks can be integrated with a wide range of door configurations. This compatibility is essential for ensuring that the locks function correctly and provide the desired level of security.
The documentation also references the use of the DL-Windows software for managing firmware updates and system integration. This software allows users to monitor the status of the locks, apply firmware updates, and configure system settings. It is an essential tool for maintaining the performance and security of the access control system.
Overall, firmware updates and system integration are critical components of the installation process for Arrow mortise locks. By following the manufacturer's recommendations for firmware updates and system integration, users can ensure that their locks operate optimally and provide the desired level of security.
Installation and Configuration Best Practices
To ensure a successful installation and configuration of Arrow mortise locks in Networx Trilogy systems, it is important to follow best practices that prioritize accuracy, compatibility, and system performance. The documentation provides a foundation for these best practices by referencing installation templates, programming instructions, and firmware updates.
One of the most important best practices is to use the appropriate installation templates for the specific lock model and door type. The documentation references templates for the DL1200ET, DL1300ET, and PDL1300ET models when installed with the Arrow S1200/S1250 mortise lock. These templates are designed to ensure that the lock is properly aligned with the door and frame, which is essential for both functionality and security.
Another best practice is to follow the manufacturer's programming instructions carefully. The documentation includes programming instructions for various models, including the DL1200ET, DL1300ET, and PDL1300ET. These instructions outline how to configure the lock for different functions, such as access levels, entry/exit modes, and alarm settings. It is important to test the lock after programming to ensure that it operates as intended.
Firmware updates are also an important part of the installation process. The documentation references firmware updates for various lock models, ensuring that the locks operate optimally within the system. Firmware updates should be applied according to the manufacturer's recommendations to ensure that the locks remain secure and functional.
In addition to following installation templates and programming instructions, it is also important to consider system compatibility. The documentation references the use of specific exit devices and door hardware with Networx Trilogy systems, ensuring that the locks can be integrated with a wide range of door configurations. This compatibility is essential for ensuring that the locks function correctly and provide the desired level of security.
Finally, it is important to consult the manufacturer's documentation and technical support resources for any questions or concerns during the installation process. The documentation references various technical support resources, including the Tech Library, Software, and Professional Training Classes. These resources can provide valuable guidance for ensuring a successful installation and configuration of Arrow mortise locks in Networx Trilogy systems.
Conclusion
The installation of Arrow mortise locks in Networx Trilogy systems requires careful attention to detail and adherence to manufacturer specifications. The documentation provides a comprehensive set of installation templates, programming instructions, and firmware updates to ensure that the locks operate optimally within the system. These resources are essential for ensuring compatibility, functionality, and security.
Installation templates are a critical component of the process, as they ensure that the lock is properly aligned with the door and frame. Programming instructions are also important for configuring the lock for different functions, such as access levels, entry/exit modes, and alarm settings. Firmware updates are necessary for maintaining the performance and security of the lock and should be applied according to the manufacturer's recommendations.
System compatibility is another important consideration, as the locks must be integrated with a wide range of door hardware and exit devices. The documentation references specific exit devices and door hardware that are compatible with Networx Trilogy systems, ensuring that the locks can be used in various applications.
Overall, following best practices for installation and configuration is essential for ensuring that Arrow mortise locks function correctly and provide the desired level of security. By consulting the manufacturer's documentation and technical support resources, users can ensure a successful installation and integration of Arrow mortise locks into their access control systems.
Sources
- Installation Instructions for DL1200ET, DL1300ET, and PDL1300ET with Arrow S1200/S1250
- Programming Instructions for DL1200ET, DL1300ET, and PDL1300ET
- Firmware - Lock DL6500 Networx V58g
- DL-Windows V5 User Guide (LATEST)
- DL-Windows V4.0.1 User Guide
- DL1200ET, DL1300ET, PDL1300ET Installation Instructions for Arrow S1200/S1250
- DL1200ET, DL1300ET, PDL1300ET Installation Template for Arrow S1200/S1250
- ETDLN, ETPDLN Installation Instructions and Template for Arrow S1200/S1250
- DL1225ET, DL1325ET, PDL1325ET Installation Template for Jackson 1095
- DL6100 Programming Instructions
- DL6500, ETDLN Programming Instructions
- DL6600, PDL6600 Mortise Installation Template (with "Door Monitoring", WI2036)
- DL2700 Programming Instructions
- DL2700 Installation Instructions
- DL2700 Parts List With Exploded View
- DL2700WP Parts List With Exploded View
- DL2750WP Parts List With Exploded View
- DL3000 Parts List With Exploded View
- DL3000 Programming Instructions
- DL3000WP Parts List With Exploded View
- DL3000WP Wiring Instructions
- DL3500 & DL3500EX Programming Instructions
- DL3500DB, DL3500CR, Installation Instructions
- DL3500EX Installation Instructions
- DL3500EX Spindle & Roll Pin Installation Instructions
- DL4100 Enhancement---Privacy Terminated on Exit Only
- DL5200 Double Sided Trilogy marketing materials
- DL5200 Programming Instructions
- DL5300 Programming Instructions
- DL6100 / PDL6100 Networx Wireless Lock Spec Sheet
- DL6100 Programming Instructions
- DL6500, ETDLN Programming Instructions
- DL6500, PDL6500 Mortise Installation Template (WI1003)
- DL6600, PDL6600 Mortise Installation Template (with "Door Monitoring", WI2036)
- Door Position Indicator Switch Misalignment for models PDL4100, PDL4500, DL4100, DL4500
- Door Prep for 2-1/8" auxiliary deadbolt
- SE-DTM III Conversion Kit, Microprocessor Upgrade Installation & Setup Instructions
- Software Enhancement kit for SE-DTM. Installation instructions for upgrading existing DTM to work with DL-Windows version 2.7 release.
- Trilogy Tailpiece Diagram
- Trilogy Locks
- "Residency/Privacy" 4100 / 4500 Series Marketing Spec Sheet (v.1)
- "Residency/Privacy" 4100 / 4500 Series Marketing Spec Sheet (v.2)
- "Residency/Privacy" DL4100 & DL4500 Programming Instructions
- "Residency/Privacy" PDL4100 & PDL4500 Programming Instructions
- 2017 Alarm Lock Price Book
- Addendum to the 4500 Series Installation Instructions
- Alarm Lock Privacy Function Wiring
- Alarm Lock Tiered School Security Solutions Flyer
- Alarm Lock Trilogy Brochure (ALA494)
- Alarm Lock Trilogy Database Tool (MS Access)
- Alternative method to "Default" any Alarm Lock Lockset
- ArchiTech Step Up Sheets
- ASA Strike Plate for All Alarmlock CR (Non-Dead Bolt) Mortise Locks
- ASA Strike Plate Template for All Alarm Lock Dead Bolt Mortise Locks
- Buildings Profit Center flier
- Business Profit Center Flier (ALA487)
- Convert a DL or PDL Cylindrical Lockset to a small format (BEST) Interchangeable Core Cylinder
- Correct Way to Remove Inside Housing From Spindle
- Daycare Profit Center Flier (ALA486)
- Daylight Saving Time Firmware
- DK3000 and PDK3000 Installation Instructions
- DK3000 Programming Manual
- DL And PDL Series Installation Instructions For All Cylindrical Type Locksets (2 1/8" Bore)
- DL-Windows V4.0.1 User Guide
- DL-Windows V5 User Guide (LATEST)
- ETDLN, ETPDLN Installation Instructions and Template For Sargent Model 8800
- ETDLN, ETPDLN Installation Instructions and Template For Von Duprin Model 99
- ETDLN, ETPDLN Installation Instructions and Template For Yale Model 7100
- ETDLN, ETPDLN, Installation Instructions and Template For Marks Model M9900
- ETDLN, ETPDLN, Installation Instructions for Sargent Models 8800, 12-8800, 8888, 12-8888, WS-8800, & 12-WS 8800
- Exit Trim: Networx Circuit Board Plug & Socket Connections
- Firmware - Gateway V3.81
- Firmware - Gateway V3.86
- Firmware - Gateway V3.89
- Firmware - Gateway V3.91
- Firmware - Gateway V3.95
- Firmware - Lock DL6100 Networx V56k
- Firmware - Lock DL6500 Networx V58e
- Firmware - Lock DL6500 Networx V58g
- Firmware - Lock ETDLN V62e
- Firmware - Lock ETDLN V62g
- Firmware - Lock ETPDLN Networx V61L
- Firmware - Lock ETPDNiRx Networx V78c
- Firmware - Lock ETPDNiRx Networx V78v (beta)
- Firmware - Lock ETPDNRX Networx V70a
- Firmware - Lock ETPLN Networx V63.c
- Firmware - Lock NETPDK / NETDK V65a
- Firmware - Lock PDL6100 Networx V55s
- Firmware - Lock PDL6100 Networx V55t
- Firmware - Lock PDL6200 Networx V67k
- Firmware - Lock PDL6500 Networx V57f
- Firmware - Lock PDL6500 Networx V57i
- Firmware - Lock PDL6600 Networx V68d
- Firmware - Lock PDL6600 Networx V68j
- Firmware - Lock PDL7100 Networx V66d
- Firmware - Lock PDL8200 Networx V75h
- Firmware - Lock PDL8200 Networx V75w (Beta)
- Firmware - Lock PDL8600 Networx V79b
- Firmware - Lock PL6100 Networx V59c
- Firmware - Lock PL6100 Networx V59d